Hematology Analyzer Hem-o-test 2000Vet
 |
- 3-part differentation of WBC for Dog, Cat and Horse, 23 parameters + 3 histograms
- Low sample volume: 10μl blood
- Unique dilute program, independent HGB detection system
- Automatic probe cleaning and sample dilution
- Data storage of 30000 samples with histograms
Technical specification
Parameters
WBC, Lymph, Mid, Gran, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV,
PLT, MPV, PDW, PCT, WBC Histogram, RBC Histogram, PLT Histogram, P-LCR.
Principles
- Electrical resistance for counting and SFT method for hemoglobin.
Specification
- Aperture Diameter 70 μm
- 10 uL sample volume
- Throughput: 35 samples/hour
- Automatic and manual calibration
- Automatic dilution when power on/off
- High voltage cleaning after each measuremnet
- QC method: X-B, L-J, SD, CV
Carryover
- WBC<0.5%, RBC<0.5%, HGB<0.5%, PLT<2%
Operating Environment
- Temperature 15°C - 30°C
- Humidity 10% - 85%
Printout
- Thermal recorder, printer
- Optional external printer
PowerRequirement
175-265V - 50/60HZ
Dimension
390X460X400 mm(W*D*H)
Net Weight
20Kg
|
|
Hematology Analyzer Hem-o-test 2100Vet
 |
- 3-part differentation of WBC for Dog, Cat and Horse, 23 parameters + 3 histograms
- Low sample volume: 10μl blood
- Unique dilute program, independent HGB detection system
- Up to 60 samples per hour
- Automatic probe cleaning and sample dilution
- Data storage of 30000 samples with histogram
Technical specification
Parameters
WBC, Lymph, Mid, Gran, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV,
PLT, MPV, PDW, PCT, WBC Histogram, RBC Histogram, PLT Histogram, P-LCR.
Principles
- Electrical resistance for counting and SFT method for hemoglobin.
Specification
- Aperture Diameter 70 μm
- 10 uL sample volume
- Throughput: 60 samples/hour
- Automatic and manual calibration
- Automatic dilution when power on/off
- High voltage cleaning after each measuremnet
- QC method: X-B, L-J, SD, CV
Carryover
- WBC<0.5%, RBC<0.5%, HGB<0.5%, PLT<2%
Working mode
- Double counting pathway+ Independent HGB detection system
-
Operating Environment
- Temperature 15°C - 30°C
- Humidity 10% - 85%
Printout
- Thermal recorder, printer
- Optional external printer
PowerRequirement
175-265V - 50/60HZ
Dimension
390X460X400 mm(W*D*H)
Net Weight
25Kg
|
|
Semi-auto Chemistry Analyzer Chem-o-test Vet
> |
- 8 species of animals available and 8 additionsl species for user to costomize
- Up to 250 test items
- 7 wavelengths optic system avoiding outer disturbance /wavelength: 340-700nm)
- open reagent
- Low carryover
- Reaction curve display
Technical Specification
Specifications
- Application: Veterinary clinics, pet hospitals or animal reseach institutions, etc.
- Test items: ≥250
- Flow cell: quartz flow cell 32uL
- With both shipping and cuvette system
- Lamp: PHILIP 6V 10W
- Measurement range: 0-2.5Abs
- Resolution: 0.001Abs(display),0.0001Abs(calculation)
- Temperatur control: Peltier 37°C, 30°C, 25°C%plusmn;0.1°C
- Repeatability: <1%
Method
-
Kinetic, End-point, Linearity end-point, Non-Linearity end-point, Absorbency, Sample blank, Multi-standards, Velocity, Calculation,
Fixed Time, bichromatic etc.
Wavelength Range
- 7 wavelengths optic system advoiding outer disturbance,
- Wavelength range: 340 nm-700 nm;
- Filter Wavelengths: 340, 380, 405, 492, 510, 546, 578, 630nm + 1 free position
- Wavelength precision: ±2nm
Quality control
- Quality control for all tests,
- Statistic and print quality control parameters automatically wth QC curves;
- Program: Add or delete test items easily according to the condition, modify the test parameters;
- Display Dynamic curves at real time, visually react the process;
- Dormant automatically for the lamp to prolong it's lifespan
- Input 8 standard curves at most in testing with multi-standard method;
- Open reagent
Data communication RS-232 serial port
PowerRequirement
AC 220V±15%, 50-60 Hz, 100W
Output
- Inner thermal printer
- External parallel printer
Display 240X128 LCD
Interface RS-232 serial port
Dimension 330mm X 355 mm x 126 mm (L*W*H)
Weight 8Kg
|
|
Urine Analyzer Urin-o-test Vet
 |
- 8 species of animals available
- Open reagent strip
- Cold light source with long shelf life
- Automatic calibration makes more accurate
- Tests save automatically after power off
- Memory: 1000 samples, 11000 tests
- Large LCD display
Specifications
- Test items: PH, Nitrite, Protein, Ascorbic Acid, Glucose, Bilirubin, Blood, Urobilinogen, Ketone, Specific Gravity,
Leukocyte
- Method: Dual-wavelength Reflectance Photometry
- Display: Large 240*128 graphic LCD with function to adjust screen's angel
- Throughput: up to 120 tests per hour
- Printer: Inner Thermal printer and port for external printer
- Wavelength: 450nm, 550nm, 650nm
- Memory: 1000 samples, 11000 tests
- Test mode: Normal mode
- Power Requirement 220VAC±10% 50W
- Working Environment: Temperature: 10°C-30°C, Humidity: 20%-80%
- Dimension: 360mm X 282mm X 115mm (L*W*H)
- Weight:6kg
|
|
Coagulometer Koag-o-test Vet
 |
- 1-channel analyzer with optical clot detection
- 1 test position with 5 cuvettes for sample preparation at
37°C
- 2 positions for reagent
Test Items
Physical Data
- Dimension: 250mm x 250mm x 112mm (L*W*H)
- Input/Output: Built-in thermal printer with paper 57mm width
RS-232 serial port supports external printer
- Display: 192*64 Graphical LCD
- Power Requirement: 220VAC±10% 60W
|
|

|
|